高级检索
当前位置: 首页 > 详情页

Effect of biomechanical properties on myopia: a study of new corneal biomechanical parameters(Open Access)

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [a]Clinical College of Ophthalmology, Tianjin Medical University, No.4, GansuRoad, Heping District, Tianjin 300020, China [b]Department of Ophthalmology,The 1st People’s Hospital of Yunnan Province, Jinbi Rd 157#, Kunming650031, China [c]Department of Ophthalmology, The Affiliated Hospital of Kunming Science and Technology University, Jinbi Rd 157#, Kunming650031, China [d]Tianjin Eye Hospital, Tianjin Eye Institute, Tianjin KeyLaboratory of Ophthalmology and Visual Science, Nankai University AffiliatedEye Hospital, Tianjin, China [e]UPMC Eye Center, University of PittsburghSchool of Medicine, Pittsburgh, PA, USA
出处:
ISSN:

关键词: Corneal biomechanics Corneal stress-strain index Myopia

摘要:
Background: To assess the corneal stress-strain index (SSI), which is a marker for material stiffness and corneal biomechanical parameters, in myopic eyes. Methods: A total of 1054 myopic patients were included in this study. Corneal visualisation Scheimpflug technology was used to measure the SSI. Corneal biomechanics were assessed using the first and second applanation times (A1-and A2-times); maximum deflection amplitude (DefAmax); deflection area (HCDefArea); the highest concavity peak distance (HC-PD), time (HC-time), and deflection amplitude (HC-DefA); integrated radius (IR); whole eye movement (WEM); stiffness parameter (SP-A1;, biomechanically corrected intraocular pressure (BIOP); and Corvis biomechanical index (CBI). Scheimpflug tomography was used to obtain the mean keratometery (Km) and central corneal thickness (CCT). According to the spherical equivalent (SE) (low myopia: SE ≥ − 3.00D and high myopia: SE ≤ − 6.00D.), the suitable patients were divided into two groups. Results: The mean SSI value was 0.854 ± 0.004. The SSI had a positive correlation with A1-time ((r = 0.272), HC-time (r = 0.218), WEM (r = 0.288), SP-A1 (r = 0.316), CBI (r = 0.199), CCT (r = 0.125), bIOP (r = 0.230), and SE (r = 0.313) (all p-values<0.01). The SSI had a negative correlation with HCDefA (r = − 0.721), HCDefArea (r = − 0.665), HC-PD(r = − 0.597), IR (r = − 0.555), DefAmax (r = − 0.564), and Km (r = − 0.103) (all p-values<0.01). There were significant differences in SSI (t = 8.960, p<0.01) and IR (t = − 3.509, p<0.01) between the low and high myopia groups. Conclusions: In different grades of myopia, the SSI values were lower in eyes with higher SEs. It indicates that the mechanical strength of the cornea may be compromised in high myopia. The SSI was positively correlated with the spherical equivalent, and it may provide a new way to study the mechanism of myopia. © 2020, The Author(s).

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2023]版:
大类 | 4 区 医学
小类 | 3 区 眼科学
JCR分区:
出版当年[2019]版:
Q3 OPHTHALMOLOGY
最新[2023]版:
Q3 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [a]Clinical College of Ophthalmology, Tianjin Medical University, No.4, GansuRoad, Heping District, Tianjin 300020, China [b]Department of Ophthalmology,The 1st People’s Hospital of Yunnan Province, Jinbi Rd 157#, Kunming650031, China [c]Department of Ophthalmology, The Affiliated Hospital of Kunming Science and Technology University, Jinbi Rd 157#, Kunming650031, China
通讯作者:
通讯机构: [a]Clinical College of Ophthalmology, Tianjin Medical University, No.4, GansuRoad, Heping District, Tianjin 300020, China [d]Tianjin Eye Hospital, Tianjin Eye Institute, Tianjin KeyLaboratory of Ophthalmology and Visual Science, Nankai University AffiliatedEye Hospital, Tianjin, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:82478 今日访问量:0 总访问量:681 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 云南省第一人民医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西山区金碧路157号