机构:[1]PET‑CT Center, the First People’s Hospital of Yunnan Province, Kunming 650032, Yunnan Province,China医技片PET/CT云南省第一人民医院[2]Department of Radiation, the First People’s Hospital of Yunnan Province, Kunming 650032, YunnanProvince, China云南省第一人民医院[3]Yunnan Key Laboratory of Primate Biomedical Research, Institute of Primate TranslationalMedicine, Kunming University of Science and Technology, Kunming 650093, Yunnan Province, China
This study aimed to develop and validate a novel rabbit fixator made from a thermoplastic mask for awake imaging experiments. When heated in a hot-water bath at 65-70 °C for 2-5 min, the thermoplastic mask became soft and could be molded to fit over the entire body of an anesthetized rabbit (4 ml of 3% pentobarbital sodium solution by intramuscular injection). Twenty rabbits were randomly divided into fixator (n = 10) and anesthesia (n = 10) groups. The animals' vital signs, stress hormones (cortisol and adrenaline), and subjective image quality scores for the computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) scanning were measured and compared. Phantom CT, MRI and PET studies were performed to assess the performance with and without the thermoplastic mask by using image agents at different concentrations or with different radioactivity. The respiration rate (RR), systolic blood pressure (SBP), diastolic blood pressure (DBP), peripheral capillary oxygen saturation (SpO2) and body temperature (T) decreased after anesthesia (all P < 0.05) but did not significantly decrease after fixation (all P > 0.05). The heart rate (HR), cortisol and adrenaline did not significantly decrease after either anesthesia or fixation (all P > 0.05). The subjective image quality scores for the CT and MRI images of the head, thorax, liver, kidney, intestines and pelvis and the subjective image quality scores for the PET images did not significantly differ between the two groups (all P > 0.05). For all examined organs except the muscle, 18F-FDG metabolism was lower after fixation than after anesthesia, and was almost identical of liver between two groups. The phantom study showed that the CT values, standard uptake values and MR T2 signal values did not differ significantly with or without the mask (all P > 0.05). A novel rabbit fixator created using a thermoplastic mask could be used to obtain high-quality images for different imaging modalities in an awake and near-physiological state.
基金:
National Natural Science Foundation of ChinaNational Natural Science Foundation of China (NSFC) [81760306]; Basic Research on Application of Joint Special Funding of Science and Technology Department of Yunnan Province-Kunming Medical University [2018FE001]; High-level Talent Project of Health in Yunnan Province [D-2018011]; Ten Thousand People Plan in Yunnan Province [YNWR-QNBJ-2018-243]
第一作者机构:[1]PET‑CT Center, the First People’s Hospital of Yunnan Province, Kunming 650032, Yunnan Province,China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
Lu Rencai,Hou Li,Wang Siyu,et al.A novel rabbit fixator made of a thermoplastic mask for awake imaging experiments.[J].SCIENTIFIC REPORTS.2021,11(1):doi:10.1038/s41598-021-81358-6.
APA:
Lu Rencai,Hou Li,Wang Siyu,She Bo,He Hong...&Wang Shaobo.(2021).A novel rabbit fixator made of a thermoplastic mask for awake imaging experiments..SCIENTIFIC REPORTS,11,(1)
MLA:
Lu Rencai,et al."A novel rabbit fixator made of a thermoplastic mask for awake imaging experiments.".SCIENTIFIC REPORTS 11..1(2021)