高级检索
当前位置: 首页 > 详情页

Gadolinium deposition in the brain is related to various contrast agents: a matched case-control study.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of MRI, The First People's Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, Kunming, 650032, Yunnan, China
出处:
ISSN:

摘要:
To assess the relationship between gadolinium deposition in the brain and various gadolinium-based contrast agents (GBCAs) and to explore confounding variables.The study group included 87 patients with multiple enhanced brain magnetic resonance imaging (MRI) examinations of which 48 patients were in the linear GBCA group (33 patients in gadopentetate dimeglumine group and 15 patients in gadobenate dimeglumine group) and 39 patients in the macrocyclic GBCA group (22 patients in gadobutrol group and 17 patients in gadoterate meglumine group). The control group included 87 normal participants who were matched regarding age, sex, MRI machine and imaging sequences to the study cohort. T1 signal intensity (SI) ratios of the dentate nucleus to the pons (DN/pons) and of the globus pallidus to the frontal white matter (GP/FWM) in both groups were calculated and compared. The relationships between SI ratios and confounding variables were analysed.Significant differences were detected between two linear GBCA groups and control groups in T1 SI ratios of the DN/pons and GP/FWM (all p<0.001). There were no differences for two the macrocyclic GBCA groups compared with matching control groups (all p>0.05). T1 SI ratios of the linear GBCA group were significantly higher than those of the macrocyclic GBCA group (p<0.001). In the linear GBCA group, the T1 SI ratios of the DN/pons correlated moderately positively with the number of GBCA administrations (r=0.643, p<0.001), and MRI machine and sequence used.Increased T1 SI could be observed after repeated administrations of linear GBCA. T1 SI of the DN correlated with the number of linear GBCA administrations, and detection might be affected by MRI machine and sequence.Copyright © 2022 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2021]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Department of MRI, The First People's Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, Kunming, 650032, Yunnan, China
共同第一作者:
通讯作者:
通讯机构: [1]Department of MRI, The First People's Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, Kunming, 650032, Yunnan, China [*1]The First People’s Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, No. 157 Jinbi Road, Kunming, 650032, Yunnan, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:82325 今日访问量:0 总访问量:681 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 云南省第一人民医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西山区金碧路157号