高级检索
当前位置: 首页 > 详情页

Peripapillary vessel density correlates with visual field mean sensitivity in highly myopic eyes

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Kunming Med Univ, Affiliated Hosp 1, Dept Ophthalmol, Kunming 650032, Yunnan, Peoples R China [2]Dazhou Cent Hosp, Dept Ophthalmol, Dazhou 635099, Peoples R China [3]First Peoples Hosp Yunnan Prov, Kunming 650011, Yunnan, Peoples R China [4]Yunnan Univ, Affiliated Hosp, Dept Ophthalmol, Kunming 650051, Yunnan, Peoples R China [5]Nanjing Med Univ, Affiliated Hosp 1, Dept Ophthalmol, Nanjing 210000, Peoples R China
出处:
ISSN:

摘要:
Purpose: To identify the global and regional distribution of peripapillary vessel density (pVD) and try to find out the relationships between pVD and the visual field mean sensitivity (VFMS) in healthy myopic eyes. Design: Prospective cross-sectional study. Methods: Two hundred and twenty-two participants (393 eyes) with myopia (myopic refractive error < - 0.5 diopters) from two clinical centers were recruited in this study and were divided into 4 groups according to the spherical equivalent (SE): Group1:- 0.5D >= SE> - 6.00D, Group2: - 6.00D >= SE > - 8.00D, Group3:- 8.00D >= SE > -10.00D, Group4:SE <=-10.00D.The pVD assessed with optical coherence tomography angiography (OCTA) was quantified in 8 sectors. Peripapillary retinal nerve fibre layer (pRNFL) imaging was performed with SD-OCT. Visual field (VF) tests were performed with the 30-2 SITA standard program on the Humphrey 750I Visual Field Analyzer and were grouped into 8 regions that matched the structure. Results: The pRNFL had no significant difference in all groups (p=0.422). The average pVD were significantly lower in group 4 (47.61 +/- 6.58) than in group 2 and 3 (51.49 +/- 3.21, 50.48 +/- 3.43 respectively) (p < 0.05). While both pVD in group2 and 3 were statistically lower than group1 (52.77 +/- 2.86). The average VFMS was significantly lower in group 4 (901.85 +/- 386.54) than other three groups (1169.15 +/- 328.94, 1081.77 +/- 338.83, 1076.89 +/- 358.18, for group1,2,3 respectively). The pVD and VFMS were positively correlated in group3 (r= 0.184) and group4 (r= 0.476) (p < 0.05). Linear regression analysis demonstrated that VFMS were positively associated with pVD especially in temporal and nasal quadrants in myopic eyes. Conclusions: The pVD shows a significant positive correlation with VFMS in highly myopic eyes with SE <=- 8.00D. We suggest that pVD measurement by OCTA could be a sensitive and useful method for monitoring myopic functional change.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 2 区 医学
小类 | 2 区 医学:研究与实验
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 医学:研究与实验
JCR分区:
出版当年[2021]版:
Q1 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q1 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Kunming Med Univ, Affiliated Hosp 1, Dept Ophthalmol, Kunming 650032, Yunnan, Peoples R China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:82494 今日访问量:0 总访问量:681 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 云南省第一人民医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西山区金碧路157号