高级检索
当前位置: 首页 > 详情页

A comparison of capillary electrophoresis and next-generation sequencing in the detection of immunoglobulin heavy chain H and light chain kappa gene rearrangements in the diagnosis of classic hodgkin's lymphoma

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]First Peoples Hosp Yunnan Prov, Dept Pathol, 157 Jinbi Rd, Kunming 650032, Yunnan, Peoples R China [2]Kunming Univ Sci & Technol, Affiliated Hosp, 157 Jinbi Rd, Kunming 650032, Yunnan, Peoples R China
出处:
ISSN:

关键词: Capillary electrophoresis next-generation sequencing classic hodgkin's lymphoma gene rearrangement

摘要:
This study aimed to compare the application value of capillary electrophoresis and next-generation sequencing for immunoglobulin (IG) gene rearrangement in the diagnosis of classic Hodgkin's lymphoma. Twenty paraffin-embedded specimens from patients with classic Hodgkin's lymphoma were screened. For gene rearrangement detection, the ABI 3500 Genetic Analyzer and ABI Ion GeneStudio S5 Plus sequencing system were used, respectively, and the results were compared. Five cases with monoclonal rearrangements (25%, 5/20) were detected by Capillary Electrophoresis, and positivity for the FR1, FR2, FR3, and IGk loci was 5%, 10%, 10%, and 15%, respectively; 12 cases with monoclonal rearrangements (60%, 12/20) were detected by Next-generation Sequencing where the positivity of the above corresponding loci were 35%, 45%, 50%, and 30%, respectively. Among the 20 samples, 6 IGk clonal rearrangements were detected, and the usage frequency (66.7%) of IGkJ4 was the highest in the IGkJ subgroup. The usage frequency of IGkV1 and IGkV3 in the GkV sub-group was 33.3% and 33.3%, respectively. Twelve immunoglobulin heavy chain (IGH) clonal rearrangements were detected among the 20 samples, and the order of usage frequency in the IGH joining region J (IGHJ) subgroup was IGHJ4 > IGHJ5 > IGHJ6 > IGHJ3. The gene with the highest usage frequency in the IGH variable (IGHV) subgroup was IGHV3 (50%) and the percentage of IGHV mutations ranged from 0% +/- 11.45% with an average frequency of 3.34%. Compared with Capillary Electrophoresis, Next-generation Sequencing showed a higher positivity in the detection of gene clonal rearrangements, was more accurate in the interpretation of results.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 2 区 生物学
小类 | 2 区 生物工程与应用微生物
最新[2023]版:
大类 | 4 区 生物学
小类 | 4 区 生物工程与应用微生物
JCR分区:
出版当年[2021]版:
Q1 BIOTECHNOLOGY & APPLIED MICROBIOLOGY
最新[2023]版:
Q2 BIOTECHNOLOGY & APPLIED MICROBIOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]First Peoples Hosp Yunnan Prov, Dept Pathol, 157 Jinbi Rd, Kunming 650032, Yunnan, Peoples R China [2]Kunming Univ Sci & Technol, Affiliated Hosp, 157 Jinbi Rd, Kunming 650032, Yunnan, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [1]First Peoples Hosp Yunnan Prov, Dept Pathol, 157 Jinbi Rd, Kunming 650032, Yunnan, Peoples R China [2]Kunming Univ Sci & Technol, Affiliated Hosp, 157 Jinbi Rd, Kunming 650032, Yunnan, Peoples R China [*1]Department of Pathology, The First People’s Hospital of Yunnan Province [*2]The Affiliated Hospital of Kunming University of Science and Technology, No. 157 Jinbi Road, Xishan District, Kunming 650032, Yunnan, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:82587 今日访问量:0 总访问量:681 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 云南省第一人民医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西山区金碧路157号