机构: [1]Graduate School, Kunming Medical University, Kunming, China. [2]Department of Orthopedics, 920th Hospital of Joint Logistics Support Force, PLA, Kunming, China. [3]Suzhou MicroPort OrthoRecon Co., Suzhou, China. [4]Department of Orthopedics, The First People's Hospital of Yunnan Province, Kunming, China.
出处:
ISSN:

关键词: 3D-printed microporous titanium artificial wrist joint artificial wrist joint prosthesis endstage carpal arthritis long-term follow up total wrist arthroplasty

摘要:
Background: Total wrist arthroplasty is an effective treatment for end-stage wrist arthritis from all causes. However, wrist prostheses are still prone to complications such as prosthesis loosening and periprosthetic fractures after total wrist arthroplasty. This may be due to the wrist prosthesis imprecise matching with patient's bone. In this study, we designed and developed a personalized three-dimensional printed microporous titanium artificial wrist prosthesis (3DMT-Wrist) for the treatment of end-stage wrist joint, and investigated its safety and effectiveness. Methods: Total wrist arthroplasty was performed using 3DMT-Wrist in 14 cases of arthritis between February 2019 and December 2021. Preoperative and postoperative visual analog scale scores, QuickDASH scores, wrist range of motion, and wrist grip strength were evaluated. Data were statistically analyzed using the paired samples t-test. Results: After 19.7 ± 10.7 months of follow-up, visual analog scale decreased from 66.3 ± 8.9 to 6.7 ± 4.4, QuickDASH scores decreased from 47.4 ± 7.3 to 28.2 ± 7.6, grip strength increased from 5.6 ± 1.4 to 17.0 ± 3.3 kg. The range of motion improved significantly in palmar flexion (30.1° ± 4.9° to 44.9° ± 6.5°), dorsal extension (15.7° ± 3.9° to 25.8° ± 3.3°), ulnar deviation (12.2° ± 3.9° to 20.2° ± 4.3°) and radial deviation (8.2° ± 2.3° to 16.2 ± 3.1). No dislocation or loosening of the prosthetic wrist joint was observed. Conclusion: Total wrist arthroplasty using 3DMT-Wrist is a safe and effective new treatment for various types of end-stage wrist arthritis; it offers excellent pain relief and maintains the range of motion.Copyright © 2023 Cai, Wang, Zhang, Zhang, Wang, Lin, Huang, Chen, Zhou, Lu and Xu.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 工程技术
小类 | 3 区 综合性期刊
最新[2023]版:
大类 | 3 区 工程技术
小类 | 3 区 综合性期刊
JCR分区:
出版当年[2022]版:
Q1 MULTIDISCIPLINARY SCIENCES
最新[2023]版:
Q1 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Q2 ENGINEERING, BIOMEDICAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Graduate School, Kunming Medical University, Kunming, China. [2]Department of Orthopedics, 920th Hospital of Joint Logistics Support Force, PLA, Kunming, China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:82587 今日访问量:0 总访问量:681 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 云南省第一人民医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西山区金碧路157号