Semiquantitative magnetic resonance imaging parameters for differentiating parotid pleomorphic adenoma from Warthin tumor

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]First Peoples Hosp Yunnan Prov, Magnet Resonance Imaging Dept, Kunming 650032, Peoples R China [2]Kunming Univ Sci & Technol, Magnet Resonance Imaging Dept, Affiliated Hosp, 157 Jinbi Rd, Kunming 650032, Peoples R China [3]First Peoples Hosp Yunnan Prov, PET CT Ctr, Kunming, Peoples R China
出处:
ISSN:

关键词: Magnetic resonance imaging (MRI) adenoma pleomorphic Warthin tumor (WT)

摘要:
Background: Accurately distinguishing between pleomorphic adenoma (PA) and Warthin tumor (WT) is beneficial for their respective management. Preoperative magnetic resonance imaging (MRI) can provide valuable information due to its excellent soft tissue contrast. This study explored the value of semiquantitative contrast-enhanced MRI parameters in the differential diagnosis of PA and WT.Methods: Data from 106 patients, 62 with PA and 44 with WT (confirmed by histopathology) were retrospectively and consecutively analyzed. The tumor-to-spinal cord contrast ratios (TSc-CR) based on the mean, maximum, and minimum signal intensity (T1-mean TSc-CR, T1-max TSc-CR, and T1-min TScCR, respectively) in the early and delayed phases were calculated on contrast-enhanced T1-weighted images as semiquantitative parameters, and then compared between PA and WT. Receiver operating characteristic (ROC) curve analysis and areas under the curve (AUCs) were used to determine the performance of these parameters in the differential diagnosis of PA from WT.Results: Except T1-min TSc-CR in the early phase, all semiquantitative MRI parameters differed significantly between PA and WT (all P<0.05). T1-max TSc-CR showed higher sensitivity {70.45% [95% confidence interval (CI): 0.548-0.832]} and specificity [70.97% (95% CI: 0.581-0.818)] and had a higher AUC [0.707 (95% CI: 0.610, 0.791)] in the early phase when using a cutoff value of 1.89. T1-max TSc-CR showed higher sensitivity [88.64% (95% CI: 0.754-0.962)], specificity [72.58% (95% CI: 0.598-0.831)], and AUC [0.854 (95% CI: 0.772-0.915)] in the delayed phase when using a cutoff value of 2.33. The sensitivity, specificity, and AUC were improved to 90.91% (95% CI: 0.783-0.975), 93.55% (95% CI: 0.843-0.982), and 0.960 (95% CI: 0.903-0.988), respectively, after combination of all semiquantitative parameters in the early and delayed phases. The two radiologists had excellent interobserver agreement on TSc-CRs [all interclassConclusions: Semiquantitative parameters using TSc-CR are valuable in distinguishing PA from WT, and a combination of these parameters can improve the differential diagnostic efficiency.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 2 区 医学
小类 | 3 区 核医学
最新[2023]版:
大类 | 2 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2022]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]First Peoples Hosp Yunnan Prov, Magnet Resonance Imaging Dept, Kunming 650032, Peoples R China [2]Kunming Univ Sci & Technol, Magnet Resonance Imaging Dept, Affiliated Hosp, 157 Jinbi Rd, Kunming 650032, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [1]First Peoples Hosp Yunnan Prov, Magnet Resonance Imaging Dept, Kunming 650032, Peoples R China [2]Kunming Univ Sci & Technol, Magnet Resonance Imaging Dept, Affiliated Hosp, 157 Jinbi Rd, Kunming 650032, Peoples R China