高级检索
当前位置: 首页 > 详情页

The independent and add-on values of radial intima thickness measured by ultrasound biomicroscopy for diagnosis of coronary artery disease

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Cardiology, The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission andChinese Academy of Medical Sciences, The State and Shandong Province Joint Key Laboratory of Translational Cardiovascular Medicine, Qilu Hospital of Shandong University,107 Wenhuaxi Road, 250012 Jinan, China [2]Department of Ultrasound, Shenzhen People’s Hospital, 3046 Shennandong Road, Luohu District, 518020 Shenzhen, Guangdong,China [3]Department of Ultrasound, First Affiliated Hospital of Kunming Medical University, 259 Xichang Road, 650032 Kunming, Yunnan, China
出处:
ISSN:

关键词: radial artery intima thickness intima-media thickness coronary artery disease ultrasound biomicroscopy

摘要:
Aims Carotid intima-media thickness (CIMT) has been widely used to risk stratify and predict coronary artery disease (CAD) despite its significant limitations. To test whether radial artery intima thickness (RIT) is closely associated with atherosclerotic risk factors, and whether RIT has an independent and additive value for diagnosis of CAD. Methods and results One hundred and sixteen consecutive CAD patients and 79 age and gender-matched healthy controls were enrolled in this study. RIT, radial media thickness, radial intima-media thickness, and CIMT were measured with a high-resolution ultrasound biomicroscopy. Binary logistic regression was used to assess association between CAD and ultrasonic parameters, biochemical biomarkers or traditional risk factors. Receiver-operating characteristic curves were plotted to compare performances of several diagnostic models. RIT was positively associated with age, systolic blood pressure, statin administration, and hypertension. The independent value of RIT for differentiating CAD was similar to that of CIMT, but the add-on value of RIT to traditional risk factors for detecting CAD was superior to that of CIMT. Moreover, addition of RIT and CIMT to traditional risk factors increased AUC for detecting CAD from 0.724 to 0.867 significantly (P = 0.003). Conclusion RIT could detect CAD independently similarly to CIMT. The add-on value of RIT to traditional risk factors for detecting CAD was superior to CIMT and addition of RIT and CIMT to traditional risk factors markedly increased the power to diagnose CAD. Thus, RIT measured by ultrasound biomicroscopy provided a novel approach to noninvasive diagnosis of CAD.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 1 区 医学
小类 | 1 区 核医学 2 区 心脏和心血管系统
最新[2023]版:
大类 | 1 区 医学
小类 | 1 区 核医学 2 区 心脏和心血管系统
JCR分区:
出版当年[2018]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2023]版:
Q1 CARDIAC & CARDIOVASCULAR SYSTEMS Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者机构: [1]Department of Cardiology, The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission andChinese Academy of Medical Sciences, The State and Shandong Province Joint Key Laboratory of Translational Cardiovascular Medicine, Qilu Hospital of Shandong University,107 Wenhuaxi Road, 250012 Jinan, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:82478 今日访问量:0 总访问量:681 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 云南省第一人民医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西山区金碧路157号