高级检索
当前位置: 首页 > 详情页

High-performance detection of an abdominal aortic aneurysm biomarker by immunosensing

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

机构: [1]Kunming Univ Sci & Technol, Dept Gen Surg, Peoples Hosp Yunnan Prov 1, Affiliated Hosp, Kunming, Yunnan, Peoples R China [2]Inst Nano Elect Engn, Kangar, Perlis, Malaysia [3]Univ Malaysia Perlis, Sch Bioproc Engn, Arau, Perlis, Malaysia [4]Kunming Univ Sci & Technol, Dept Gastroenterol, Peoples Hosp Yunnan Prov 1, Affiliated Hosp, Kunming, Yunnan, Peoples R China [5]Kunming Univ Sci & Technol, Digest Med Dept, Peoples Hosp Yunnan Prov 1, Affiliated Hosp, Kunming, Yunnan, Peoples R China
出处:
ISSN:

关键词: abdominal aortic aneurysm InterDigitated electrode sensor insulin-like growth factor 1 immunodetection

摘要:
Abdominal aortic aneurysm (AAA) is a serious, life-threatening vascular disease that presents as an enlarged area of the aorta, which is the main artery that carries blood away from the heart. AAA may occur at any location in the aorta, but it is mainly found in the abdominal region. A ruptured AAA causes serious health issues, including death. Traditional imaging techniques, such as computed tomography angiogram, magnetic resonance imaging, and ultrasound sonography, have been used to identify AAAs. Circulating biomarkers have recently become attractive for diagnosing AAAs due to their cost-effectiveness compared to imaging. Insulin-like growth factor 1 (IGF-1), a secreted hormone vital for human atherosclerotic plaque stability, has been found to be an efficient biomarker for AAA identification. In this report, immunosensing was performed by using an InterDigitated electrode (IDE) sensor to detect circulating levels of IGF-1. The detection limit of IGF-1 was found to be 100 fM with this sensor. Moreover, related protein controls (IGF-2 and IGFBP3) were not detected with the same antibody, indicating selective IGF-1 detection. Thus, immunosensing by using an IDE sensor may help to effectively diagnose AAAs and represents a basic platform for further development.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 工程技术
小类 | 4 区 生化与分子生物学 4 区 生物工程与应用微生物
最新[2023]版:
大类 | 4 区 生物学
小类 | 4 区 生化与分子生物学 4 区 生物工程与应用微生物
JCR分区:
出版当年[2019]版:
Q4 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Q4 BIOCHEMISTRY & MOLECULAR BIOLOGY
最新[2023]版:
Q2 BIOCHEMISTRY & MOLECULAR BIOLOGY Q2 BIOTECHNOLOGY & APPLIED MICROBIOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Kunming Univ Sci & Technol, Dept Gen Surg, Peoples Hosp Yunnan Prov 1, Affiliated Hosp, Kunming, Yunnan, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [4]Kunming Univ Sci & Technol, Dept Gastroenterol, Peoples Hosp Yunnan Prov 1, Affiliated Hosp, Kunming, Yunnan, Peoples R China [5]Kunming Univ Sci & Technol, Digest Med Dept, Peoples Hosp Yunnan Prov 1, Affiliated Hosp, Kunming, Yunnan, Peoples R China [*1]Department of Gastroenterology, The First People’s Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, Kunming, China. [*2]The Digestive Medicine Department, The First People’s Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, Kunming, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:82494 今日访问量:0 总访问量:681 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 云南省第一人民医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西山区金碧路157号