Comparison of the 3D-printed operation guide template technique and the free-hand technique for S2-alar-iliac screw placement(Open Access)

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Orthopedics, The First People’s Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, Kunming 650032, China. [2]Department of Orthopedics, 920 Hospital of the Joint Logistic Support Force, Kunming 650032, China.
出处:
ISSN:

关键词: 3D-printed technique Free-hand technique Operation guide template S2AI screws

摘要:
Background: To compare the safety and accuracy of the 3D-printed operation guide template technique and the free-hand technique in the placement of the S2-alar-iliac (S2AI) screw. Methods: We conducted a retrospective analysis of 47 patients undergoing S2AI screw placement in our hospital, divided into the 3D-printed operation guide template group and the free-hand screw placement group. The duration of single S2AI screw placement was documented in all patients. A postoperative CT scan was performed to assess screw placement effectiveness according to the distance from the screw tip to the breach of the cortical bone wall. Results: In total, 42 screws were placed in the guide template group, with an average screw placement duration of 151.6 ± 44.8 s. Screw placement grading was as follows: 40 screws in grade 0, two in grade 1, and none in grades 2 and 3. This grading resulted in excellent and good rates of 95.2% and 100%, respectively. In total, 52 screws were placed in the free-hand group, with an average screw placement duration of 138.3 ± 45.9 s. Screw placement grading was as follows: 42 screws in grade 0, seven in grade 1, three in grade 2, and none in grade 3. This grading resulted in excellent, good and acceptable rates 80.8%, 94.2% and 100%, respectively. Screw placement duration did not significantly differ between the groups (p > 0.05). The excellent rate of screw placement was greater in the guide template group than in the free-hand group (p < 0.05), but the good and acceptable rates did not significantly differ between the two groups (p > 0.05). Conclusion: Both techniques can be applied to S2AI screw placement. The 3D-printed guide technique is superior to the free-hand technique in terms of safety and accuracy. © 2020, The Author(s).

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 外科
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 外科
JCR分区:
出版当年[2019]版:
Q2 SURGERY
最新[2023]版:
Q2 SURGERY

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Department of Orthopedics, The First People’s Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, Kunming 650032, China. [2]Department of Orthopedics, 920 Hospital of the Joint Logistic Support Force, Kunming 650032, China.
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:82493 今日访问量:0 总访问量:681 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 云南省第一人民医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西山区金碧路157号