高级检索
当前位置: 首页 > 详情页

Double-trajectory lumbar screw placement guided by a set of 3D-printed surgical guide templates: a cadaver study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [a]Department of Orthopedics, The First People’s Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, The Key Laboratory of Digital Orthopedics of Yunnan Province, No. 157 Jinbi Road, Kunming, Yunnan [b]Department of Orthopedics, 920 Hospital of the Joint Logistic Support Force, 212 Daguan Road, Kunming, Yunnan
出处:
ISSN:

关键词: Cadaveric study Cortical bone trajectory screw Operation guide template Pedicle screw

摘要:
Background: To improve the strength of posterior spine fixation in patients with osteoporosis, some scholars have proposed a method of simultaneously inserting traditional pedicle screws and cortical bone trajectory screws into the pedicle. However, due to the difficulty of the operation and few clinical applications, the safety and accuracy of this method are still unclear. The purpose of this study was to investigate the safety and accuracy of double-trajectory lumbar screw placement guided by surgical guide templates. Methods: Six wet lumbar specimens were selected for computed tomography (CT) scanning, a three-dimensional (3D) model of the lumbar spine was established using computer software, and surgical guide templates for double-trajectory [traditional pedicle trajectory (TPT) and cortical bone trajectory (CBT)] lumbar screw placement at various segments of the lumbar spine were designed and printed using a 3D printer. Screw placement was guided only by the surgical guide template, with no fluoroscopy. Postoperative CT examination was performed to determine whether the screw penetrated the screw path and the location and depth of penetration of the cortex. The preoperative and postoperative sagittal and axial angles of CBT screws or TPT screws were also measured and compared. Results: Four screws were placed in each vertebral body of six lumbar specimens for a total of 120 screws. Screw grades: 99 screws as grade 0, 15 as grade 1, six as grade 2, and zero as grade 3. Thus, grade 0 accounted for 82.5% of the screws. No significant differences in the preoperative and postoperative angles of the screws were found (P > 0.05). Conclusions: 3D-printed surgical guide templates for double-trajectory screw placement can reduce the difficulty of surgery and the use of intraoperative fluoroscopy. Using such templates is a safe, feasible, and accurate screw placement method. © 2021, The Author(s).

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 4 区 骨科 4 区 风湿病学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 骨科 3 区 风湿病学
JCR分区:
出版当年[2020]版:
Q3 ORTHOPEDICS Q4 RHEUMATOLOGY
最新[2023]版:
Q2 ORTHOPEDICS Q3 RHEUMATOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [a]Department of Orthopedics, The First People’s Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, The Key Laboratory of Digital Orthopedics of Yunnan Province, No. 157 Jinbi Road, Kunming, Yunnan
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:83045 今日访问量:0 总访问量:682 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 云南省第一人民医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西山区金碧路157号