A New Method for Blood NT-proBNP Determination Based on a Near-infrared Point of Care Testing Device with High Sensitivity and Wide Scope.

文献详情

资源类型:
Pubmed体系:

收录情况: ◇ CSCD-C

机构: [1]National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China. [2]Beijing Runbio Biotechnology Development Co., Ltd, Beijing 100106, China. [3]No.2 People's Hospital of Dali City, Dali 671003, Yunnan, China. [4]Department of Laboratory Medicine, Beijing Hospital, National Center of Gerontology, Beijing 100730, China.
出处:
ISSN:

关键词: NT-proBNP Near-infrared POCT device Lateral flow assay

摘要:
To develop a rapid, highly sensitive, and quantitative method for the detection of NT-proBNP levels based on a near-infrared point-of-care diagnostic (POCT) device with wide scope. The lateral flow assay (LFA) strip of NT-proBNP was first prepared to achieve rapid detection. Then, the antibody pairs for NT-proBNP were screened and labeled with the near-infrared fluorescent dye Dylight-800. The capture antibody was fixed on a nitrocellulose membrane by a scribing device. Serial dilutions of serum samples were prepared using NT-proBNP-free serum series. The prepared test strips, combined with a near-infrared POCT device, were validated by known concentrations of clinical samples. The POCT device gave the output of the ratio of the intensity of the fluorescence signal of the detection line to that of the quality control line. The relationship between the ratio value and the concentration of the specimen was plotted as a work curve. The results of 62 clinical specimens obtained from our method were compared in parallel with those obtained from the Roche E411 kit. Based on the log-log plot, the new method demonstrated that there was a good linear relationship between the ratio value and NT-proBNP concentrations ranging from 20 pg/mL to 10 ng/mL. The results of the 62 clinical specimens measured by our method showed a good linear correlation with those measured by the Roche E411 kit. The new LFA detection method of NT-proBNP levels based on the near-infrared POCT device was rapid and highly sensitive with wide scope and was thus suitable for rapid and early clinical diagnosis of cardiac impairment. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 3 区 环境科学与生态学
小类 | 3 区 环境科学 3 区 公共卫生、环境卫生与职业卫生
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 环境科学 4 区 公共卫生、环境卫生与职业卫生
第一作者:
第一作者机构: [1]National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:88193 今日访问量:1 总访问量:733 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 云南省第一人民医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西山区金碧路157号