高级检索
当前位置: 首页 > 详情页

A Pilot Study of Third-Generation Dual-Source Computed Tomography for the Assessment of Global Dynamic Changes in Left Ventricular Structure and Function in a Porcine Model of Acute Myocardial Infarction

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Chongqing Medical University, Chongqing, P.R. China [2]Department of Radiology, First People’s Hospital of Yunnan, Kunming, Yunnan, P.R. China [3] Department of Radiology, Third People’s Hospital of Yunnan, Kunming, Yunnan, P.R. China [4]Kunming Medical University, Kunming, Yunnan, P.R. China [5] Department of Radiology, First Affiliated Hospital of Chongqing Medical University, Chongqing, P.R. China
出处:
ISSN:

关键词: Coronary Artery Disease Multidetector Computed Tomography Swine Ventricular Function Left

摘要:
Background: First-generation and second-generation dual-source computed tomography (DSCT) are useful for analyzing left ventricle (LV) structure and function. This pilot study aimed to investigate the feasibility and role of third-generation DSCT for the evaluation of dynamic changes in LV structural and functional characteristics in a Diannan small-ear pig model of acute myocardial infarction (AMI). Material/Methods: The model of AMI was established by balloon occlusion of the distal third of the left anterior descending (LAD) coronary artery in 14 Diannan small-eared pigs. Third-generation DSCT was performed to observe dynamic changes in LV structure and function before and after AMI was induced, with a follow-up period of 30 days. Results: The mean structural measurements at baseline included interventricular septum thickness (8.50 +/- 0.90 mm), LV anterior wall thickness (8.40 +/- 1.30 mm), LV posterior wall thickness (7.80 +/- 1.20 mm), LV end-diastolic dimension (LVEDD) (45.00 +/- 4.90 mm), and LV end-systolic dimension (LVESD) (25.90 +/- 4.10 mm). The mean functional measurements at baseline included the LV end-diastolic volume (LVEDV) (74.62 +/- 13.54 ml), LV end-systolic volume (LVESV) (23.06 +/- 7.46 ml), LV ejection fraction (LVEF) (69.29 +/- 6.83%), LV mass (86.35 +/- 14.02 g), stroke volume (SV) (51.56 +/- 9.77 ml), and cardiac output (CO) (4.22 +/- 2.14 l/min). Trends of time-dependent changes were observed for LVESV, LVEF, SV, and CO, but not for LVEDV or LV mass. Conclusions: Third-generation DSCT was validated as a tool for assessing dynamic changes in LV global function in a porcine model of AMI.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
JCR分区:
出版当年[2018]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者机构: [1]Chongqing Medical University, Chongqing, P.R. China [2]Department of Radiology, First People’s Hospital of Yunnan, Kunming, Yunnan, P.R. China
通讯作者:
通讯机构: [5] Department of Radiology, First Affiliated Hospital of Chongqing Medical University, Chongqing, P.R. China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:83045 今日访问量:0 总访问量:682 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 云南省第一人民医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西山区金碧路157号