A Pilot Study of Third-Generation Dual-Source Computed Tomography for the Assessment of Global Dynamic Changes in Left Ventricular Structure and Function in a Porcine Model of Acute Myocardial Infarction
机构:[1]Chongqing Medical University, Chongqing, P.R. China[2]Department of Radiology, First People’s Hospital of Yunnan, Kunming, Yunnan, P.R. China [3] Department of Radiology, Third People’s Hospital of Yunnan, Kunming, Yunnan, P.R. China[4]Kunming Medical University, Kunming, Yunnan, P.R. China[5] Department of Radiology, First Affiliated Hospital of Chongqing Medical University, Chongqing, P.R. China
Background: First-generation and second-generation dual-source computed tomography (DSCT) are useful for analyzing left ventricle (LV) structure and function. This pilot study aimed to investigate the feasibility and role of third-generation DSCT for the evaluation of dynamic changes in LV structural and functional characteristics in a Diannan small-ear pig model of acute myocardial infarction (AMI). Material/Methods: The model of AMI was established by balloon occlusion of the distal third of the left anterior descending (LAD) coronary artery in 14 Diannan small-eared pigs. Third-generation DSCT was performed to observe dynamic changes in LV structure and function before and after AMI was induced, with a follow-up period of 30 days. Results: The mean structural measurements at baseline included interventricular septum thickness (8.50 +/- 0.90 mm), LV anterior wall thickness (8.40 +/- 1.30 mm), LV posterior wall thickness (7.80 +/- 1.20 mm), LV end-diastolic dimension (LVEDD) (45.00 +/- 4.90 mm), and LV end-systolic dimension (LVESD) (25.90 +/- 4.10 mm). The mean functional measurements at baseline included the LV end-diastolic volume (LVEDV) (74.62 +/- 13.54 ml), LV end-systolic volume (LVESV) (23.06 +/- 7.46 ml), LV ejection fraction (LVEF) (69.29 +/- 6.83%), LV mass (86.35 +/- 14.02 g), stroke volume (SV) (51.56 +/- 9.77 ml), and cardiac output (CO) (4.22 +/- 2.14 l/min). Trends of time-dependent changes were observed for LVESV, LVEF, SV, and CO, but not for LVEDV or LV mass. Conclusions: Third-generation DSCT was validated as a tool for assessing dynamic changes in LV global function in a porcine model of AMI.
基金:
Health and Technology Program of Yunnan [2014NS261]
第一作者机构:[1]Chongqing Medical University, Chongqing, P.R. China[2]Department of Radiology, First People’s Hospital of Yunnan, Kunming, Yunnan, P.R. China
通讯作者:
通讯机构:[5] Department of Radiology, First Affiliated Hospital of Chongqing Medical University, Chongqing, P.R. China
推荐引用方式(GB/T 7714):
Wenjia Li,Liang Lyu,Weixin Yang,et al.A Pilot Study of Third-Generation Dual-Source Computed Tomography for the Assessment of Global Dynamic Changes in Left Ventricular Structure and Function in a Porcine Model of Acute Myocardial Infarction[J].Medical science monitor : international medical journal of experimental and clinical research.2019,25:7989-7997.doi:10.12659/MSM.919122.
APA:
Wenjia Li,Liang Lyu,Weixin Yang,Rongshun Zhang,Gang Wang...&Tianyou Luo.(2019).A Pilot Study of Third-Generation Dual-Source Computed Tomography for the Assessment of Global Dynamic Changes in Left Ventricular Structure and Function in a Porcine Model of Acute Myocardial Infarction.Medical science monitor : international medical journal of experimental and clinical research,25,
MLA:
Wenjia Li,et al."A Pilot Study of Third-Generation Dual-Source Computed Tomography for the Assessment of Global Dynamic Changes in Left Ventricular Structure and Function in a Porcine Model of Acute Myocardial Infarction".Medical science monitor : international medical journal of experimental and clinical research 25.(2019):7989-7997