Comparative Diagnostic Accuracy of Contrast-Enhanced Ultrasound and Shear Wave Elastography in Differentiating Benign and Malignant Lesions: A Network Meta-Analysis
机构:[1]The First People’s Hospital of Yunnan Province, Kunming, China,云南省第一人民医院[2]Chuangxu Institute of Life Science, Chongqing, China,[3]Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
Background: We performed a network meta-analysis to compare the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) and shear wave elastography (SWE) in differentiating benign and malignant lesions in different body sites. Methods: A computerized literature search of Medline, Embase, SCOPUS, and Web of Science was performed using relevant keywords. Following data extraction, we calculated sensitivity, specificity, positive likelihood ratio (LR), negative LR, and diagnostic odds ratio (DOR) for CEUS, and SWE compared to histopathology as a reference standard. Statistical analyses were conducted by MetaDiSc (version 1.4) and R software (version 3.4.3). Results: One hundred and fourteen studies (15,926 patients) were pooled in the final analyses. Network meta-analysis showed that CEUS had significantly higher DOR than SWE (DOR = 27.14, 95% CI [2.30, 51.97]) in breast cancer detection. However, there were no significant differences between CEUS and SWE in hepatic (DOR = -6.67, 95% CI [-15.08, 1.74]) and thyroid cancer detection (DOR = 3.79, 95% CI [-3.10, 10.68]). Interestingly, ranking analysis showed that CEUS achieved higher DOR in detecting breast and thyroid cancer, while SWE achieved higher DOR in detecting hepatic cancer. The overall DOR for CEUS in detecting renal cancer was 53.44, 95% CI [29.89, 95.56] with an AUROC of 0.95, while the overall DOR for SWE in detecting prostate cancer was 25.35, 95% CI [7.15, 89.89] with an AUROC of 0.89. Conclusion: Both diagnostic tests showed relatively high sensitivity and specificity in detecting malignant tumors in different organs. Network meta-analysis showed that CEUS had higher diagnostic accuracy than SWE in detecting breast and thyroid cancer, while SWE had higher accuracy in detecting hepatic cancer. However, the results were not statistically significant in hepatic and thyroid malignancies. Further head-to-head comparisons are needed to confirm the optimal imaging technique to differentiate each cancer type.
基金:
This work was supported by funding from National Natural
Science Foundation of China. Award Number 31300137 received
by RH.
第一作者机构:[1]The First People’s Hospital of Yunnan Province, Kunming, China,
通讯作者:
推荐引用方式(GB/T 7714):
Huang Rongzhong,Jiang Lihong,Xu Yu,et al.Comparative Diagnostic Accuracy of Contrast-Enhanced Ultrasound and Shear Wave Elastography in Differentiating Benign and Malignant Lesions: A Network Meta-Analysis[J].FRONTIERS IN ONCOLOGY.2019,9:doi:10.3389/fonc.2019.00102.
APA:
Huang, Rongzhong,Jiang, Lihong,Xu, Yu,Gong, Yuping,Ran, Haitao...&Sun, Yang.(2019).Comparative Diagnostic Accuracy of Contrast-Enhanced Ultrasound and Shear Wave Elastography in Differentiating Benign and Malignant Lesions: A Network Meta-Analysis.FRONTIERS IN ONCOLOGY,9,
MLA:
Huang, Rongzhong,et al."Comparative Diagnostic Accuracy of Contrast-Enhanced Ultrasound and Shear Wave Elastography in Differentiating Benign and Malignant Lesions: A Network Meta-Analysis".FRONTIERS IN ONCOLOGY 9.(2019)