高级检索
当前位置: 首页 > 详情页

Establishment of loop-mediated isothermal amplification for rapid detection of Pseudomonas aeruginosa

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Molecular Diagnosis Laboratory, Faculty of Life Science and Technology, Kunming University of Science and Technology [2]Molecular Medicine Center of Yunnan Province, Kunming, Yunnan 650500 [3]Department of Clinical Laboratory, First People's Hospital of Yunnan Province, Kunming, Yunnan 650034, P.R. China
出处:
ISSN:

关键词: Pseudomonas aeruginosa loop-mediated isothermal amplification polymerase chain reaction novel specific gene rapid detection

摘要:
Pseudomonas aeruginosa is one of the three most pathogenic bacteria that frequently cause life-threatening opportunistic human infections, pneumonia, and lower respiratory tract infections in immunocompromised hosts, particularly in the burns ward. The present study aimed to establish a loop-mediated isothermal amplification (LAMP) method for the rapid and sensitive detection of P. aeruginosa-specific gene hypothetical protein (GenBank ID: 882161). The gene was obtained through local and online BLAST, and specific primers were designed for this gene. Reaction conditions were optimized at 65 degrees C for 30 min and 80 degrees C for 2 min, whereas the reaction system contained 5.2 mM Mg2+, 8 U Bst 2.0 DNA polymerase, 1.4 mM deoxyribonucleotide and 0.2 and 1.6 mu M of the outer and inner primers, respectively. The LAMP method was evaluated using 150 P. aeruginosa and 170 non-P. aeruginosa strains. Positive reactions were observed on 150 P. aeruginosa strains, whereas all non-P. aeruginosa strains exhibited negative results. Plasmids with the specific gene and mouse blood with P. aeruginosa were used for sensitivity assay. The detection limit of LAMP was 1 bacterium/reaction. Results indicated that the LAMP method targeted to hypothetical protein is a fast, specific, sensitive, inexpensive and suitable method for detection of P. aeruginosa.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
JCR分区:
出版当年[2018]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者机构: [1]Molecular Diagnosis Laboratory, Faculty of Life Science and Technology, Kunming University of Science and Technology [2]Molecular Medicine Center of Yunnan Province, Kunming, Yunnan 650500
通讯作者:
通讯机构: [1]Molecular Diagnosis Laboratory, Faculty of Life Science and Technology, Kunming University of Science and Technology [2]Molecular Medicine Center of Yunnan Province, Kunming, Yunnan 650500 [*1]Molecular Diagnosis Laboratory, Faculty of Life Science and Technology, Kunming University of Science and Technology, 727 Jingming South Road, Kunming, Yunnan 650500, P.R. China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:82490 今日访问量:0 总访问量:681 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 云南省第一人民医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西山区金碧路157号