高级检索
当前位置: 首页 > 详情页

Accuracy of S2 alar-iliac screw placement under the guidance of a 3D-printed surgical guide template.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Orthopedics, 920th Hospital of the Joint Logistics Support Force of the Chinese People's Liberation Army, 212 Daguan Road, Xishan District, Kunming, China [2]Department of Orthopedics, First People's Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, Key Laboratory of Digital Orthopedics of Yunnan Province, 157 Jinbi Road, Xishan District, Kunming, China
出处:
ISSN:

关键词: 3D printing technology surgical guide template S2AI screw accuracy

摘要:
To evaluate the safety and accuracy of S2 alar-iliac (S2AI) screw placement guided by a three-dimensional (3D)-printed surgical guide template. The data of 27 patients treated with S2AI screws were analyzed. S2AI surgical guide templates were designed and printed, and S2AI screw placement was completed intraoperatively with the guide templates. Postoperative computed tomography (CT) was performed to measure screw path parameters, namely, the sagittal angle (SA), the transverse angle (TA), the horizontal distance (HD) between the entry point of the screw and the median sacral crest, and the vertical distance (VD) between the entry point of the screw and the lower edge of the first posterior sacral foramen. Screw placement was graded according to the Oh grading criteria. A total of 54 S2AI screws were placed. The screw grades were as follows: 52 screws were considered grade 0, two were grade 1, none were grade 2, and none were grade 3. Thus, grade 0 accounted for 96.3% of the screws. When the preoperatively planned SA (32.3° ± 2.0°), TA (42.1° ± 3.9°), HD (5.1 ± 1.1) mm, and VD (19.0 ± 2.4) mm were compared with the corresponding postoperative SA (31.9° ± 3.8°), TA (42.5° ± 4.0°), HD (4.9 ± 1.1) mm, and VD (19.1 ± 2.3) mm, no significant differences were identified (P > 0.05). S2AI screw placement assisted by a 3D-printed surgical guide is safe and accurate. Copyright © 2020. Published by Elsevier Inc.

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 外科
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 外科
JCR分区:
出版当年[2020]版:
Q3 SURGERY Q4 CLINICAL NEUROLOGY
最新[2023]版:
Q2 SURGERY Q3 CLINICAL NEUROLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]Department of Orthopedics, 920th Hospital of the Joint Logistics Support Force of the Chinese People's Liberation Army, 212 Daguan Road, Xishan District, Kunming, China [2]Department of Orthopedics, First People's Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, Key Laboratory of Digital Orthopedics of Yunnan Province, 157 Jinbi Road, Xishan District, Kunming, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:82473 今日访问量:0 总访问量:681 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 云南省第一人民医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西山区金碧路157号