高级检索
当前位置: 首页 > 详情页

Digital anatomical study and clinical application of the ideal S2 alar-lliac screw trajectory

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Department of Orthopedics, The First People’s Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, 157 Jinbi Road, Kunming, Xishan District, China
出处:
ISSN:

关键词: Spinal pelvic fixation S2AI Ideal screw trajectory

摘要:
Background To investigate the ideal trajectory for the S2AI screw and to clinically validate its safety feasibility. Methods The 3D model was reconstructed from CT data of the pelvis of 30 selected adults, and the 3D coordinate system was established with the first sacral superior endplate as the horizontal plane. A set of cutting planes was made at 3 mm intervals in the coronal plane, and the cross-sectional internal tangent circles were divided in the target area. Using the linear fitting function, the axis of 90 mm length was calculated by the least squares method for each inner tangent circle center. The diameter of the axis is gradually increased until the first contact with the cortex, and the cylindrical model is the ideal screw trajectory. The intersection of the axis and the dorsal cortex is the screw placement point, which is located by Horizon Distance (HD) and Vertical Distance (VD); the diameter of the screw trajectory (d) is the diameter of the cylindrical model; the direction of the screw trajectory is determined by Sagittal Angle (SA) and Transverse Angle (TA). The screw trajectory orientation is determined by Sagittal Angle (SA) and Transverse Angle (TA). Based on the ideal screw trajectory, the 3D printed surgical guide and freehand techniques were used to verify its safety feasibility, respectively. Results The screw placement points [HD (4.7 +/- 1.0) mm, VD (19.7 +/- 1.9) mm], screw placement directions [SA (31.3 degrees +/- 2.3 degrees), TA (42.4 degrees +/- 2.3 degrees)], and screw dimensions for the ideal screw trajectory of the S2AI were combined for analysis. (L is 90 mm, d is 13.2 +/- 1.4 mm). The S2AI screw superiority rate [96.6% (56/58)] and reasonable rate [100%] were higher in the guide group than in the freehand group [90.0% (63/70), 97.1% (68/70)], but the differences were not statistically significant (P > 0.05). Although screws invaded the cortex in both groups, there were no associated adverse events in either group. Conclusion The S2AI screw-based ideal trajectory placement is a safe, feasible and accurate method of screw placement.

基金:
语种:
WOS:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 3 区 外科
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 外科
JCR分区:
出版当年[2022]版:
Q3 SURGERY
最新[2023]版:
Q2 SURGERY

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Department of Orthopedics, The First People’s Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, 157 Jinbi Road, Kunming, Xishan District, China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Orthopedics, The First People’s Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, 157 Jinbi Road, Kunming, Xishan District, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:82490 今日访问量:0 总访问量:681 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 云南省第一人民医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西山区金碧路157号